Sign In | Join Free | My benadorassociates.com
China Xinxiang SIMO Blower Co., Ltd. logo
Xinxiang SIMO Blower Co., Ltd.
SIMO Blower Industrial Blower Fan Manufacture Experts First-class products,first-class technology, first-class service
Verified Supplier

5 Years

Home > Flue Gas Fan >

Industrial Boiler Backward Curved Centrifugal Fan High Efficiency Less Than 9000cfm

Xinxiang SIMO Blower Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Industrial Boiler Backward Curved Centrifugal Fan High Efficiency Less Than 9000cfm

Brand Name : SIMO BLOWER

Model Number : Y

Place of Origin : CHANA

Ambient Temperature : 20℃-500℃

Insulation Class : F

Impeller Testing : Dynamic Blancing Adjusting

Pressure : 2000-10000Pa

Air Volume : 2473-484756m3/h

Speed : 1450-2900rpm

Blade Number : 5-12

Application : Cement Kiln ,Boiler,Tunnel, Factory,Engineering Construction

Contact Now

Industrial Boiler Fan

Introduction

Mainly to meet the dust emission requirements of the electric arc furnace exhaust gas purification equipment, improve the workshop environment, to ensure that the dust concentration in the electric furnace working area meets the “sanitary standards for industrial enterprises”, and can also be used in various occasions with the same functional requirements.

The 5-12 series centrifugal fan is an enhanced version of the 5-11 series medium pressure centrifugal fan.

It has a larger output flow than the 5-11 series. It is also used to transport a variety of common gases and hard materials in the industrial field, the application object is exactly the same as 5-11 series fan.

Mainly circulating fluidized bed system, smoke exhaust, material drying, industrial dust collector / filtration system, flue gas desulfurization, flue gas denitrification, industrial boiler induced air, cement production line, industrial waste heat recovery device, mineral powder sintering ( sintering machine), Coke production (coking furnace), etc, is especially suitable for various harsh conditions such as high temperature, wear and corrosion.

Technical Parameters

Parameter Value
Type Induced Draft Fan
Pressure

684-8687Pa

Air Volume

590.4-700735㎥/h

Insulation Class F
Voltage 380V/50Hz
Ambient Temperature 20℃-500℃
Blade Number 9-19,7-28,9-26
Blade Type Backward Curved
Speed 1450-2900rpm
Motor AC Motor

Advantages and Features

1. It is capable of outputting a higher outlet pressure while providing more gas flow with lower noise. Stable operation at higher media temperatures.

2. The fan speed can be flexibly set by matching different pulley diameters to make the fan run at the highest efficiency point and reduce energy waste.

3. Motor sliding guides are provided for easy tensioning of the belt to reduce energy loss due to belt slack.

4. The bearing housing is reserved for temperature and vibration sensor mounting positions, for convenient to install the fan operation monitoring device.

5. Use liquid lubricant, it is not necessary to open the bearing housing to replace and fill the oil. The bearing housing is provided with an observation window for easy observation of the quality and stock of the lubricating oil.

6. The bearing housing uses a labyrinth mechanical seal, a unique Leak proof oil design inside, a vent hole at the top, and a sealant on the joint, completely eliminating the possibility of oil leakage in the bearing housing.

7. The impeller is annealed to completely eliminate the internal stress generated during welding, ensuring that the impeller does not undergo creep and cracks.

8. The impeller is subjected to a high standard of dynamic balance correction to ensure stable operation of the fan.

9. After the production is completed, all products are tested for running and vibration values for reliable operation.

FAQ

1. What parameters need to be provided when you design the Heat Dissipation Power Plant Blower Fan?

Answers: Air flow, total pressure or static pressure, inlet temperature, local voltage and frequency, Altitude etc.

If there is flammable and explosive gas, or big dust loading in the medium, please also inform the designer.

2. How about your company’s pre-sales service and after-sales service?

Answers: Before our cooperation, we have the professional technical team to help you make the technical solution according to your working condition, to make sure the centrifugal fan efficiency operation.

After sales service, we will offer 12 months’ repairing service, and provide lifelong follow-up services. Besides, our engineers are available for going abroad to offer the repairing service.

3. Does your company have qualifications?

Answers: SIMO Blower has obtained ISO 9001-2008, CE, TUV certifications and so on.

Industrial Boiler Backward Curved Centrifugal Fan High Efficiency Less Than 9000cfm


Product Tags:

industrial boiler backward curved centrifugal fan

      

high efficiency backward curved centrifugal fan

      

9000cfm industrial centrifugal fan

      
Quality Industrial Boiler Backward Curved Centrifugal Fan High Efficiency Less Than 9000cfm for sale

Industrial Boiler Backward Curved Centrifugal Fan High Efficiency Less Than 9000cfm Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Xinxiang SIMO Blower Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)