Sign In | Join Free | My benadorassociates.com
China Xinxiang SIMO Blower Co., Ltd. logo
Xinxiang SIMO Blower Co., Ltd.
SIMO Blower Industrial Blower Fan Manufacture Experts First-class products,first-class technology, first-class service
Verified Supplier

5 Years

Home > Cement Fan >

Heavy Duty Low Pressure Cement Fan Rotary Kiln Exhaust SIMO Blower

Xinxiang SIMO Blower Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Heavy Duty Low Pressure Cement Fan Rotary Kiln Exhaust SIMO Blower

Brand Name : SIMO

Model Number : SIMO Blower 4-09

Certification : CE, ISO9001:2008,TUV

Place of Origin : Henan China

MOQ : 1 Set

Price : 300-5000 USD

Payment Terms : T/T, L/C, Payment Term Is Negotiable

Supply Ability : 500 Sets Per Month

Delivery Time : 15-35 Days

Packaging Details : Export Wooden Case Packing, Steel pallet Packing

Type : Centrifugal Fan

Feature : High Performance

Drivetrain : V-belt Driven

Impeller : Dynamic Balanced

Color : Customer's Requirement

Delivery time : 30 days

Contact Now

Heavy Duty Low Pressure Carbon Steel Cement Rotary Kiln Exhaust Blower Fan

Introduction

The 4-09 series large-flow centrifugal fan is suitable for conveying clean air or light materials at normal temperature, most commonly used in industrial furnaces for air supply, light particle/powder/crush/fiber transportation, air drying/cooling of materials, ventilation and smoke exhaust, and other areas.

No viscous substances are allowed inside the gas, and the dust and hard particles contained in the gas are larger than 150 mg/m3, and the gas temperature does not exceed 80°C.

Heavy Duty Low Pressure Carbon Steel Cement Rotary Kiln Exhaust Blower Fan is widely used in the cement industry, building materials industry, environmental protection industry, metallurgical industry, power industry projects such as large-scale dust collector, industrial boilers, ventilation systems, cooling.

Centrifugal fan is applied in industrial boiler, (centrifugal fan can be applied in industrial boiler,) it also can be applied in industrial kilns, blast furnace, Industrial waste heat recovery device, Electrolytic aluminium production line air purification system and other industrial work environment.

According to fan parameters you need, SIMO can make centrifugal blower fan technical solution for you. So please provide air capacity, pressure range, medium temperature, voltage and other requirements, more details will help us design suitable technical solution for you.

Technical data

PRODUCT PARAMETERS
Blower Fan
Application
Temperature Normal temperature air, Hot air
Air composition Clean air, Dusty air, Corrosive gas, Combustible gas,Powder materials, Light particle materials
Blower Fan
Performance
Impeller diameter

280-600

mm
Speed of mainshaft

960-2900

rpm
Pressure range

198-3187

Pa
Flow range

844-15456

m3/h
Blower Fan
Structure
Blade

Backward

Impeller support SWSI (Single Width, Single Inlet), Impeller overhung.
Drivetrain

V-Belt

Can assign
Lubrication Oil bath lubrication
Bearing cooling Air cooling, Water cooling, Oil cooling
Blower Fan
System
configuration
Motor ABB, SIEMENS, WEG, TECO, SIMO, Chinese brand…

Can assign

Impeller Q235, Q345, SS304, SS316, HG785, DB685...

Casing, Air inlet cone,

Air inlet damper

Q235, Q345, SS304, SS316, HG785, DB685...
Main shaft 45# steel(High-strength carbon structural steel), 42CrMo, Stainless steel...
Bearing FAG, SKF, NSK, ZWZ…
Blower Fan
Optional
components
System base frame, Protective screening,Silencer, Inlet & Outlet pipeline compensator,
Inlet & Outlet flange, Damper, Electric actuator, Shock isolator, Diaphragm coupling, Fluid coupling, Motor rain cover, Temperature sensor, Vibrating sensor, Soft starter, Inverter, Special Electrical Motor,System monitoring Instrument, Lube system, Overhead lube tank etc.


Advantages and Features

1. When the pressure requirement is met, a large gas flow can be output, and the noise is very low.

2. The fan speed can be flexibly set by matching different diameters of belt pulley to make the fan run at the highest efficiency point and reduce energy waste.

3. Motor sliding guides are provided for easy tensioning of the belt to reduce energy loss due to belt slack.

4. When the airflow resistance is increased, the motor load will be automatically reduced and the motor will not be burnt.

5. In the case of a monolithic bracket, the installation is very simple and requires little support from a professional technician.

6. After the production is completed, all products are tested for running and vibration values for reliable operation.

FAQ

1. What parameters need to be provided when you design the industrial centrifugal fans?

Answers: Air flow, total pressure or static pressure, inlet temperature, local voltage and frequency, Altitude etc.

If there is flammable and explosive gas, or big dust loading in the medium, please also inform the designer.

2. How about your company’s pre-sales service and after-sales service?

Answers: Before our cooperation, we have the professional technical team to help you make the technical solution according to your working condition, to make sure the centrifugal fan efficiency operation.

After sales service, we will offer 12 months’ repairing service, and provide lifelong follow-up services. Besides, our engineers are available for going abroad to offer the repairing service.

3. Does your company have qualifications?

Answers: SIMO Blower has obtained ISO 9001-2008, CE, BV certifications and so on.

Heavy Duty Low Pressure Cement Fan Rotary Kiln Exhaust SIMO Blower

Heavy Duty Low Pressure Cement Fan Rotary Kiln Exhaust SIMO Blower


Product Tags:

forced draught fan

      

process fans in cement plant

      
Quality Heavy Duty Low Pressure Cement Fan Rotary Kiln Exhaust SIMO Blower for sale

Heavy Duty Low Pressure Cement Fan Rotary Kiln Exhaust SIMO Blower Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Xinxiang SIMO Blower Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)